Wecon hmi Muti-link function and settings

Multi-link provides an economical and flexible solution that allows multiple human-machines to communicate with each other via RS485.In the operation of Multi-link, one human-machine works as a the master, the others work as the slave. Only the master can communicate with the PLC and receive data from it. And the slaves all receive data from the master. Therefore, every slave must have its own station number that allows the master to interact with it, which means interacting with the PLC.


Wecon hmi Muti-link settings:




Ⅰ.Connection Mode

An example of communication between a PLC and four human-machines is shown in the figure below. Note that human-machines usually communicate with each other via RS485 and every slave must have its own station number. When the system has just one slave, human-machines can also communicate with each other via RS232.


Ⅱ. Parameter settings of Multi-link Communication



Here are the operation procedures of setting communication parameters of Multi-link.

1.Select 【System Parameter】/【Connections and communication】, then select “add” in the screen. Select communication interface of Multi-link in the option of “communication interface” and “Multi-Link Protocol”in the option of “device type”.

2. Set the parameters of the master and the slave,the corresponding number and station number of the slave. 
Notes: 
The more slaves, the slower the communication speed may be. 
The station numbers of the slave must be consecutive numbers starting from one without repeating. 
The parameters of the master and the slave must be the same.
The order of the protocol must be the same when choosing the protocol of the master and the slave.

3.After setting the parameters above, select【Tool】/【Project Build】.Then you can download it to the human-machine.


Multi-Link Protocol settings: 



Notes If a system has one master and slaves, we should change the number of the slave in the option of master setting 
 and change the HMI station number in the option of slave setting. 
The station number of HMI increase by one, that is if the number of the slave is two, then the station number of the first slave is one and the second slave is two, etc. Other settings are the same as above.


Ⅲ. Notes

    Please note the following points when using Multi-Link.
1. Please make sure that the projects of the master and the slaves are the same except the parameters of them.
2. The external address used in the scripts must be added to 【Project Configuration】/【System Parameter】/【Multi-Link Extra Address】when using scripts.
3. The interface parameters of the master and the slaves must be the same.
4. The order of the protocol must be the same when choosing the protocol of the master and the slaves.
5. The station numbers of the slaves must be consecutive numbers starting from one without repeating.
6. The more slaves, the slower the communication speed may be.
7. Suggest communicating via RS485 when selecting Multi-Link Protocol. When the system has just one slave, human-machines can also communicate with each other via RS232.
8. The external address used in the scripts must be added to 【Project Configuration】/【Multi-Link Data Area】.

2014年3月20日星期四

Wecon LX plc product introduction

Wecon LX plc has 14, 20, 32, 40 and 60 I/O for choices.  The comprehensive frequency of first two channels is up to 400 KHz: hardware is 400 KHZ and software is 200 KHZ; the latter 4 channel is 10k Max. Basic instruction is 0.1 micro second per command, and application instruction is 1 micro second per command.
 


 


Wecon LX plc not only no acceleration/deceleration's single pulse output, but also acceleration/deceleration's single pulse output is available via different command programmatically. Still available output methods are "MultiSession", "forward&reverse" and so on.
 
The counting methods of LX series plc are incremental mode, Pulse + direction mode and AB - phase mode.
incremental mode
Pulse + direction mode
 
AB - phase mode
LX2N series plc support Ontology PID control, and AutoTuning function is available. In order to enhance accuracy, users can get best time for sampling time and PID value via autotuning function. PID control is widely applied in temperature, flow, speed, tension, pressure control and so on. LX2N series plc has 2 communication ports: COM1 and COM2. COM1 support RS422, COM2 support RS422 and RS485. A,B terminal of plc is the external RS485 wiring terminal.
 
In additional, LX transistor plc supported 2- channel high-speed pulse output, 2 times running speed of other plc at same price level. All of LX series plcs are completely compatible with fx1s plc or fx2n plc software. There are exclusive plc extension modules for LX 60 I/O plc, it will be available for all of LX2N plc in future.

2014年2月19日星期三

Wecon A7 series industrial panel pc introduction

 Wecon A7 series industrial panel pc windows ce 5.0 system, and support NET Framework 2.0/3.5, WIFI wireless Ethernet is optional. There are 4.3-inch, 7-inch, 10.2-inch and 10.4-inch for choices.

A7 series industrial panel pc main hardware parameters:
* ARM9 2416 400MHZ CPU
* The whole series adopt TFT true color LCD, with 65536 colors and brightness of up to 250 lumens; supporting 4.3-inch, 7-inch, 10.2-inch and 10.4-inch;
* 128MB Built-in Flash
* a USB HOST; a USB DEVICE
* DDR2 64MB memory
* Support RS232/RS485/RS422, multiple serial ports
* Support CANBUS
* Support Video Input
* Support audio output
* Using the embedded installation

Wecon A7 series industrial pc Software Configuration:

*  WINCE 5.0 system
*  NET Framework 2.0 (also support NET Framework 3.5)
*  IE browser (optional)
*  RDP function (Remote Desktop) (optional)
*  OPC SERVER (optional)
*  WIFI wireless Ethernet (optional)
*  Serial Drivers (RS232/RS485/RS422), can support up to 921600 baud rate
*  USB mouse, keyboard, ergonomic devices (e.g. scanner)
*  USB mini printer (South Korea SEWOO brand) (optional)
*  FTP SERVER (optional)
*  CITRIX client (optional)
*  HTTP SERVER (optional)
*  Media Player (optional)
*  Support Chinese & English dynamic switch
*  CEPC System built-in configuration tool
*  ACTIVESYNC dynamic debugging tool

Note: Optional represents that WINCE system kernel-image can be customized according to users’ needs. And Wecon A7 series industrial panel pc don't support LINUX and ANDROID system so far.

A7 series industrial panel pc pictures:
4.3 inch industrial panel pc picture
 
7 inch industrial panel pc picture
 
10.2 inch industrial panel pc picture
 
10.4 inch industrial panel pc picture

2013年8月28日星期三

Wecon LEVI-777T Bus Paperless Recorde

LEVI 777T has a socket to interface the high capacity CF card, it also can monitor multiple data collection modules via RS485 BUS. The collection data can be saved into the CF card, the data type is CSV format or encrypted CSV format. The collection data can be exported to USB disk and processed it in the PC.
LEVI series HMI supports maximum 4G bytes CF card, and can save maximum 5 years data. And in HMI, you can query the data by history data reports, history trend graph components.
The current data for all channels is as the following.